DIGITAL RCD TESTER
DIGITAL RCD TESTER - T2712ELFor More Information visit : http://www.shopprice.com.au/digital+rcd+tester
Test & Measurement - RCD Testers - RCD Test Instruments
T2712EL - DIGITAL RCD TESTER - TIME & CURRENT
The TopTronic T2712EL is a compact hand held RCD tester. It is designed
for professional use to obtain accurate values of the Trip Time with
the selection on a dial switch of the trip current.
Resistors are used to pass the trip current between earth and active. Therefore a correction factor in percentage is available on the display for adjustment according to the line voltage.
The trip time is measured to a maximum of 3.000 seconds, while the fault current is selectable on a range from 3 to 500mA. The unit has been designed for ease of operation whilst maintaining safety, reliability and accuracy.
Features:
Three basic tests
- Wiring test
- Line Voltage to Earth
- Tripping time
Menu driven and easy to use.
Has a LED wiring check function to check wiring prior to test.
The phase at which to start the test can be selected (0 or 180).
Dynamic battery check.
Microprocessor controlled.
Tough rugged meter, designed to give accurate measurements in harsh environments.
To complete the test, connect the unit, and check the LED displays that indicate the wiring is correct. Check that the line voltage is within tolerance. Set the trip current on the selector and hit the test button. Once the test is complete, the operator can view the following on the LDC display.
Circuit voltage
Percentage error current (from nominal voltage)*
Disconnection time
Polarity at opening
Over Temperature Protection
* Voltage fluctuations are taken in to account by the microprocessor, and the percentage error current will be the same as the voltage fluctuations shown on the display.
Safety and Conformance
Safety - Meets IEC 1010-1 CAT III 300V
EMC - Meets EN55011,
Overload Protection
Over-voltage, Over-temperature and Fuse protected.
Ranges and Accuracy Function Range Accuracy
System Voltage 240V 2% 1V
Voltage Tester 20~280VAC 1V 2%
Trip Settings 3,5,10,15,20,30,50,
100,150,250,300,500mA % Proportional
to Voltage
Disconnection Time 0 - 2.999 Seconds 2% 1mS
Timer 1mS 2mS
Phase Start Selection - 180 -
Operating Temperature -5 to 45C -
Ordering information
TOPTRONIC part number T2712EL
Each unit is supplied in a robust case with test leads, batteries and instruction manual.
Batteries: - 6 of AA batteries (included)
Size: 200 x 85 x 55mm
Weight: 540g
Resistors are used to pass the trip current between earth and active. Therefore a correction factor in percentage is available on the display for adjustment according to the line voltage.
The trip time is measured to a maximum of 3.000 seconds, while the fault current is selectable on a range from 3 to 500mA. The unit has been designed for ease of operation whilst maintaining safety, reliability and accuracy.
Features:
Three basic tests
- Wiring test
- Line Voltage to Earth
- Tripping time
Menu driven and easy to use.
Has a LED wiring check function to check wiring prior to test.
The phase at which to start the test can be selected (0 or 180).
Dynamic battery check.
Microprocessor controlled.
Tough rugged meter, designed to give accurate measurements in harsh environments.
To complete the test, connect the unit, and check the LED displays that indicate the wiring is correct. Check that the line voltage is within tolerance. Set the trip current on the selector and hit the test button. Once the test is complete, the operator can view the following on the LDC display.
Circuit voltage
Percentage error current (from nominal voltage)*
Disconnection time
Polarity at opening
Over Temperature Protection
* Voltage fluctuations are taken in to account by the microprocessor, and the percentage error current will be the same as the voltage fluctuations shown on the display.
Safety and Conformance
Safety - Meets IEC 1010-1 CAT III 300V
EMC - Meets EN55011,
Overload Protection
Over-voltage, Over-temperature and Fuse protected.
Ranges and Accuracy Function Range Accuracy
System Voltage 240V 2% 1V
Voltage Tester 20~280VAC 1V 2%
Trip Settings 3,5,10,15,20,30,50,
100,150,250,300,500mA % Proportional
to Voltage
Disconnection Time 0 - 2.999 Seconds 2% 1mS
Timer 1mS 2mS
Phase Start Selection - 180 -
Operating Temperature -5 to 45C -
Ordering information
TOPTRONIC part number T2712EL
Each unit is supplied in a robust case with test leads, batteries and instruction manual.
Batteries: - 6 of AA batteries (included)
Size: 200 x 85 x 55mm
Weight: 540g